Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Stud Length
0.500 inches
Overall Diameter
3.500 inches
Environmental Protection
Shock resistant and vibration resistant
Mounting Bolt Circle Diameter
3.160 inches
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.688 inches
Meter Body Diameter Behind Mounting Flange
2.800 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 threaded stud
Scale Graduation Type
Nonlinear single indicator single range
Measurement Range
-6.0/+3.0 decibels above or below one milliwatt single indicator single range
Measurement Range
-6.0 to 3.0 decibels above or below one milliwatt single indicator single range
Mounting Stud Diameter
0.138 inches
Scale Selection Method
Terminal
Features Provided
Knife edge pointer and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug
Special Markings
Red zero graduation mark, red zero set
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Designed, manufactured and tested in accordance w/mil-m-10304
Style Designator
Round flush mtg
Supplementary Features
75 ohms internal resistance
Fsc Application Data
Test set, elect. Equip.
Description
Meter,audio Level