Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
0.112 inches
Scale Division Quantity
2 single indicator single range
Overall Diameter
2.687 inches
Environmental Protection
Airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Mounting Bolt Circle Diameter
2.468 inches
Furnished Items And Quantity
Nut 3; lockwasher 5; seal 1; shunt wire 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
333.0 microamperes
Dial Scale Marking Color
Black single indicator single range and green single indicator single range and orange single indicator single range
Dial Scale Marking Color
Black and green and orange single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.375 inches
Meter Body Diameter Behind Mounting Flange
2.203 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Scale Marking
Low; 0; high
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 screw and 2 solder lug
Special Markings
O w/circle through scale and around 0; low and shaded green left of 0; high and shaded red right of 0; swr
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
On back, sealed do not open; conforms to mil-m-10304
Style Designator
Round flush mtg
Fsc Application Data
Test set, elect. Equip.