Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Reliability Indicator
Established
Mounting Hole Diameter
0.150 inches
Scale Division Quantity
20 single indicator 1st range
Scale Division Quantity
30 single indicator 2nd range
Overall Diameter
3.510 inches
Mounting Bolt Circle Diameter
3.160 inches
Furnished Items And Quantity
Nuts 7, washers 7
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
1.281 inches
Meter Body Diameter Behind Mounting Flange
2.800 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
3 unthreaded hole
Scale Graduation Type
Linear single indicator all ranges
Measurement Range
-1.0/+1.0 volts, dc single indicator 1st range
Measurement Range
-3.0/+3.0 volts, dc single indicator 2nd range
Measurement Range
-1.0 to 1.0 volts, dc single indicator 1st range
Measurement Range
-3.0 to 3.0 volts, dc single indicator 2nd range
Scale Selection Method
Terminal
Features Provided
Magnetic shield
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Fsc Application Data
Electrical and electronic properties measuring and testing instruments