Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
100.0
Center To Center Distance Between Mounting Facilities Parallel To Length
2.875 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches
Overall Height
3.375 inches
Overall Width
3.750 inches
Mounting Stud Length
0.630 inches
Environmental Protection
Airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Furnished Items And Quantity
Nut 8; lockwasher 6; seal 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
25.0 microamperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-0.5/+0.5 at full scale single indicator single range
Accuracy In Percent
-0.5 to 0.5 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
0.880 inches
Meter Body Diameter Behind Mounting Flange
2.680 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
Nonlinear single indicator single range
Mounting Stud Diameter
0.138 inches
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect equip
Description
Meter,arbitrary Scale