Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
2600.0
Center To Center Distance Between Mounting Facilities Parallel To Length
3.376 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
3.376 inches
Overall Height
4.422 inches
Overall Width
4.422 inches
Mounting Hole Diameter
0.312 inches
Environmental Protection
Shock resistant and vibration resistant and watertight
Furnished Items And Quantity
Nut 6; washer 12; o ring 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
5.0 amperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-1.5/+1.5 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
2.813 inches
Meter Body Diameter Behind Mounting Flange
3.930 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Nonlinear single indicator single range
Measurement Range
+0.0/+4000.0 amperes, ac single indicator single range
Scale Selection Method
Terminal
Features Provided
Magnetic shield and shatterproof glass and zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-16034
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect. Equip.