Description
2.470 inches maximum overall length, steel corrosion resisting material, enamel semigloss surface treatment.
Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
Between 0.120 inches and 0.130 inches
Overall Diameter
2.695 inches
Environmental Protection
Cold resistant and heat resistant and shock resistant and submersible and vibration resistant and watertight
Mounting Bolt Circle Diameter
2.440 inches
Furnished Items And Quantity
Nut 5; washer 5
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
5.0 volts
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.430 inches
Meter Body Diameter Behind Mounting Flange
2.150 inches
Movement Type
Moving iron vane
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Nonlinear single indicator single range
Measurement Range
+0.0/+4.0 amperes, ac single indicator single range
Features Provided
Luminous scale marking and magnetic shield and zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 threaded stud
Special Markings
Sealed do not open on back of meter; plus sign above positive terminal
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-10304/4
Style Designator
Round flush mtg
Fsc Application Data
Test set, elect. Equip.