Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
3000.0
Mounting Hole Diameter
0.138 inches
Overall Diameter
2.690 inches
Mounting Bolt Circle Diameter
2.440 inches
Furnished Items And Quantity
Nut 5; washer 5
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Three hole/stud bolt circle
Sensitivity Rating
150.0 millivolts
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
1.390 inches
Meter Body Diameter Behind Mounting Flange
2.050 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
3 screw and 3 unthreaded hole
Scale Graduation Type
Nonlinear single indicator single range
Measurement Range
-10.0/+10.0 decibels single indicator single range
Measurement Range
-10.0 to 10.0 decibels single indicator single range
Features Provided
Magnetic shield and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug and 2 threaded stud
Special Markings
Sealed do not open on back of meter
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Supplementary Features
Ext magnet
Fsc Application Data
Test set, elect. Equip.
Description
Meter,audio Level