Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
1500.0
Center To Center Distance Between Mounting Facilities Parallel To Length
3.805 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
0.750 inches
Overall Height
1.481 inches
Overall Width
4.183 inches
Mounting Hole Diameter
0.154 inches
Scale Division Quantity
6 single indicator single range
Environmental Protection
Shock resistant and vibration resistant and watertight
Furnished Items And Quantity
Lamp holder 2; nut 4; lock washer 4
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Unable To Decode
Unable to decode or unable to decode
Meter Depth Behind Mounting Flange
2.737 inches
Meter Body Width Behind Mounting Flange
3.433 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Red single indicator single range
Mounting Facility Type And Quantity
4 threaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+0.0/+30.0 milliamperes, dc single indicator single range
Meter Body Height Behind Mounting Flange
1.481 inches
Features Provided
Rfi shielding and self-illumination facility and zero adjuster
Circuit Attachment Method And Quantity
4 threaded stud
Special Markings
Lamp, meter on back
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Rectangular flush mtg
Supplementary Features
Horizontal mtg
Fsc Application Data
Test set, elect. Equip.