Circuit Current For Which Designed
Ac
Dielectric Withstanding Voltage In Volts
3000.0
Center To Center Distance Between Mounting Facilities Parallel To Length
1.856 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
1.856 inches
Overall Height
2.375 inches
Overall Width
2.375 inches
Mounting Hole Diameter
0.170 inches
Scale Division Quantity
80 single indicator single range
Frequency Rating
400.0 hertz
Environmental Protection
Airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Furnished Items And Quantity
Nut 8; lockwasher 6; seal 1
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Frequency Response Range
+360.000/+440.000 hertz
Sensitivity Rating
40.0 decibels
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-2.0/+2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.375 inches
Meter Body Diameter Behind Mounting Flange
2.060 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
+360.0/+440.0 hertz single indicator single range
Scale Selection Method
Terminal
Features Provided
Magnetic shield and zero adjuster
Circuit Attachment Method And Quantity
2 threaded stud
Special Markings
On back, sealed do not open
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Complies with mil-m-10304
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect. Equip.
Description
Meter,electrical Frequency