Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
800.0
Center To Center Distance Between Mounting Facilities Parallel To Length
3.375 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
3.375 inches
Overall Height
8.750 inches
Overall Width
8.750 inches
Mounting Hole Diameter
0.313 inches
Scale Division Quantity
80 single indicator single range
Environmental Protection
Shock resistant and vibration resistant
Furnished Items And Quantity
Mtg hdw 4; term. Hdw 2
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Sensitivity Rating
20.0 milliamperes
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-1.0/+1.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
3.656 inches
Meter Body Diameter Behind Mounting Flange
3.960 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Scale Marking
Deg f; 400; 500; 600; 700; 800; 900; 1000; 1100; 1200
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Features Provided
Zero adjuster
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 threaded stud
Special Markings
Off at 0 deflection
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Complies w/ansi standards c39.1
Style Designator
Rectangular flush mtg
Fsc Application Data
Test set, elect. Equip.
Description
Meter,special Scale