Circuit Current For Which Designed
Dc
Dielectric Withstanding Voltage In Volts
800.0
Center To Center Distance Between Mounting Facilities Parallel To Length
3.375 inches
Center To Center Distance Between Mounting Facilities Parallel To Width
3.375 inches
Overall Height
4.422 inches
Overall Width
4.422 inches
Mounting Hole Diameter
0.313 inches
Scale Division Quantity
80 single indicator single range
Environmental Protection
Corrosion resistant and shock resistant
Furnished Items And Quantity
Nut 6; washer 6
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Four hole/stud rectangular/square
Dial Scale Marking Color
Black single indicator single range
Accuracy In Percent
-1.5/+1.5 at full scale single indicator single range
Meter Depth Behind Mounting Flange
2.251 inches
Meter Body Diameter Behind Mounting Flange
3.960 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator single range
Pointer Color
Black single indicator single range
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
Linear single indicator single range
Measurement Range
-400.0/+400.0 volts, dc single indicator single range
Scale Selection Method
Terminal
Features Provided
Self-illumination facility and zero adjuster
Criticality Code Justification
Feat
Movement Suspension Method
Taut band
Circuit Attachment Method And Quantity
2 threaded stud
Nuclear Hardness Critical Feature
Nonhardened
Special Test Features
Conforms to mil-m-16034
Style Designator
Rectangular flush mtg
Supplementary Features
Ruggedized
Fsc Application Data
Test set, elect. Equip.