Circuit Current For Which Designed
Ac and dc
Dielectric Withstanding Voltage In Volts
1000.0
Mounting Hole Diameter
0.150 inches
Scale Division Quantity
15 single indicator 1st range
Scale Division Quantity
20 single indicator 2nd range
Overall Diameter
4.500 inches
Mounting Bolt Circle Diameter
4.124 inches
Indicator Type
Dial w/pointer
Installation Design
Panel
Mounting Arrangement Style
Six hole/stud bolt circle
Sensitivity Rating
200.0 microamperes
Dial Scale Marking Color
Black single indicator all ranges
Accuracy In Percent
-2.0/+2.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
1.438 inches
Meter Body Diameter Behind Mounting Flange
3.594 inches
Movement Type
Moving coil, permanent magnet
Background Color
White single indicator all ranges
Pointer Color
Black single indicator all ranges
Mounting Facility Type And Quantity
6 unthreaded hole
Scale Graduation Type
Linear single indicator all ranges
Measurement Range
+0.0/+1.0 volts, ac single indicator 2nd range
Measurement Range
+0.0/+3.0 volts, ac single indicator 1st range
Features Provided
Knife edge pointer and zero adjuster
Movement Suspension Method
Jewel pivot base
Circuit Attachment Method And Quantity
2 solder stud
Special Markings
On rear of meter: positive terminal has plus sign; fs 200uadc for sensitivity; + 50 ohms for coil resistance
Nuclear Hardness Critical Feature
Nonhardened
Style Designator
Round flush mtg
Supplementary Features
Internal resistance: 400 to 500 ohms
Fsc Application Data
Test set, elect. Equip.