Circuit Current For Which Designed
Ac or dc
Overall Depth
2.200 inches
Overall Width
3.750 inches
Environmental Protection
Cold resistant and heat resistant and humidity resistant and shock resistant and vibration resistant
Furnished Items And Quantity
Spare fuse 1; operator manual 1
Indicator Type
Digital display and bargraph
Installation Design
Bench or hand held
Display Type
Liquid crystal
Display Digit Quantity
3.5
Measurement Range
+0.0/+10.0 amperes, ac single indicator 1st range
Measurement Range
+0.0/+10.0 amperes, dc single indicator 2nd range
Measurement Range
+0.0/+1000.0 volts, ac single indicator 13th range
Measurement Range
+0.0/+1000.0 volts, dc single indicator 15th range
Measurement Range
+0.0/+32.0 megohms single indicator 4th range
Measurement Range
+0.0/+320.0 milliamperes, ac single indicator 7th range
Measurement Range
+0.0/+320.0 kilohms single indicator 3rd range
Measurement Range
+0.0/+320.0 volts, ac single indicator 12th range
Measurement Range
+0.0/+320.0 volts, dc single indicator 14th range
Measurement Range
+0.0/+3200.0 microamperes, ac single indicator 5th range
Measurement Range
+0.0/+320.0 milliamperes, dc single indicator 8th range
Measurement Range
+0.0/+320.0 millivolts, ac single indicator 9th range
Measurement Range
+0.0/+320.0 millivolts, dc single indicator 10th range
Measurement Range
+0.0/+320.0 ohms single indicator 11th range
Measurement Range
+0.0/+3200.0 microamperes, dc single indicator 6th range
Scale Selection Method
Switch and terminal
Features Provided
Autoranging and electrical overload protection and internal battery accommodation and portable and warning feature
Criticality Code Justification
Zzzy
Accuracy Rating
Porm 0.1 pct of reading plus 1 digit single indicator 10th range
Accuracy Rating
Porm 0.1 pct of reading plus 1 digit single indicator 14th range
Accuracy Rating
Porm 0.1 pct of reading plus 1 digit single indicator 15th range
Accuracy Rating
Porm 0.2 pct of reading plus 1 digit single indicator 3rd range
Accuracy Rating
Porm 0.3 pct of reading plus 2 digits single indicator 11th range
Accuracy Rating
Porm 0.75 pct of reading plus 2 digits single indicator 8th range
Accuracy Rating
Porm 0.75 pct of reading plus 2 digits single indicator 2nd range
Accuracy Rating
Porm 0.75 pct of reading plus 2 digits single indicator 6th range
Accuracy Rating
Porm 1.0 pct of reading plus 1 digit single indicator 4th range
Accuracy Rating
Porm 1.5 pct of reading plug 2 digits single indicator 7th range
Accuracy Rating
Porm 1.5 pct of reading plus 2. Digits single indicator 1st range
Accuracy Rating
Porm 3.0 pct of reading plus 3 digits single indicator 13th range
Accuracy Rating
Porm 4.0 pct of reading plus 10 digits single indicator 12th range
Accuracy Rating
Porm 4.0 pct of reading plus 10 digits single indicator 9th range
Accuracy Rating
Prom 1.5 pct of reading plus 2 digits single indicator 5th range
Display Color
Black single indicator all ranges
Circuit Attachment Method And Quantity
2 clip and 2 wire lead
Operating Voltage Rating In Volts
9.0 ac
Style Designator
Portable
Supplementary Features
Hold button to capture and display readings; 31 segment bar graph for peaking, nulling, capacitor checking
Fsc Application Data
Test set, elect. Equip.
Reference Number Differentiating Characteristics
Reference number differentitiating material will be iaw naval inventory control point activity hx quality control, manufacturing and testing specifications available at the dla icp