Indicating temperature control (NSN 6685-01-143-9510)
Special Features
Capiliary tube 0.062 in. Diameter by 32.0 in. Lg; bulb sensing element 0.375 in. By 11.5 in. Lg with an o-ring 0.437 in. Od by 0.062 in. Thk; total length of capiliary tube and sensing element 43.500 in; panel mtg clamp provided
Case Material
Aluminum
Case Surface Treatment
Paint
Operating Tempurature Range
-210.0/+280.0 degrees fahrenheit
Fragility Factor
Moderately delicate
Maximum Voltage Rating In Volts
125.0 ac or 250.0 ac
End Application
6530-01-120-2658
Inclosure Type
Encased
Current Rating In Amps
15.0
Terminal Location
Back corner
Power Source
External
Mounting Method
Panel
Storage Type
General purpose warehouse
Terminal Type And Quantity
3 wire lead
Maximumlength
3.500 inches
Maximumwidth
3.750 inches
Maximumheight
1.875 inches
Sensing Element Type And Location
Bulb remote
Part Name Assigned By Controlling Agency
Control temp indicating 125/250v ac 15 amps 2.5x3.75" alum case
Phase
Single
Functional Description
Use to control temperature increments of 2 degrees farenheit