2357 part numbers
463-595 NSN 6625-00-613-7537 Cross Reference: 476-0465-010
482-327 NSN 6625-00-613-7556 Cross Reference: 476-0464-020
482-328 NSN 6625-00-613-7563 Cross Reference: 476-0464-010
27502 NSN 6625-00-618-5990
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.003 inches overall length
  • 0.122 inches mounting hole diameter
  • 2.680 inches overall diameter
M-154A NSN 6625-00-619-1053 Cross Reference: 900999-9294, M-154
  • dc circuit current for which designed
  • 3.530 inches overall length
  • 4.822 inches center to center distance between mounting facilities parallel to length
  • 0.906 inches center to center distance between mounting facilities parallel to width
  • 1.000 inches overall height
9-2150-209 NSN 6625-00-619-4166 Cross Reference: 3675008-041, MK706-15
  • dc circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 7.466 inches overall length
  • 6.050 inches center to center distance between mounting facilities parallel to length
  • 0.725 inches center to center distance between mounting facilities parallel to width
9-2150-211 NSN 6625-00-619-4176 Cross Reference: 1001-E633, 2150X2135BC0211, 3675008-043
  • dc circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 7.730 inches overall length
  • between 6.043 inches and 6.057 inches center to center distance between mounting facilities parallel to length
  • between 0.718 inches and 0.732 inches center to center distance between mounting facilities parallel to width
3675008-045 NSN 6625-00-619-4177 Cross Reference: 9-2150-213, MK706-44
  • dc circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 7.730 inches overall length
  • between 6.043 inches and 6.057 inches center to center distance between mounting facilities parallel to length
  • between 0.718 inches and 0.732 inches center to center distance between mounting facilities parallel to width
9-2150-215 NSN 6625-00-619-4180 Cross Reference: 1001-E714, 2150X2135BC0215, 3675008-047, MK706-5
2150VRB4-20DCMA NSN 6625-00-619-4181 Cross Reference: 9-2150-218, MK706-9
  • dc circuit current for which designed
  • 7.496 inches overall length
  • 6.050 inches center to center distance between mounting facilities parallel to length
  • 0.725 inches center to center distance between mounting facilities parallel to width
  • 1.520 inches overall height
HS3Z NSN 6625-00-623-3029 Cross Reference: 20821898, 54B6835H13
  • dc circuit current for which designed
  • 1.922 inches overall length
  • 0.125 inches mounting hole diameter
  • 3.484 inches overall diameter
  • 3.160 inches mounting bolt circle diameter
331C147H02 NSN 6625-00-624-0137 Cross Reference: 125R, 1521 CLASS 52, 560-938
  • dc circuit current for which designed
  • 2.130 inches overall length
  • between 0.120 inches and 0.130 inches mounting hole diameter
  • 2 single indicator single range scale division quantity
  • 2.695 inches overall diameter
575R478H12 NSN 6625-00-624-7315 Cross Reference: A10969
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 1.458 inches overall length
  • 1.674 inches overall diameter
  • seal 1; lockwasher 2 furnished items and quantity
3191-1132P1 NSN 6625-00-625-7824 Cross Reference: 3191-1132P1ISSUE1, 4R
D5474638PC11 NSN 6625-00-628-1731
  • panel installation design
  • black single indicator single range dial scale marking color
  • white single indicator single range background color
365 NSN 6625-00-628-8082 Cross Reference: 1131519, 1131519G1, 631-16805, M-2147
S1545-1010P2 NSN 6625-00-635-4347 Cross Reference: S1545-1010ISSUE3PT2SH1AND2
  • dc circuit current for which designed
  • 2.890 inches overall length
  • 2.250 inches center to center distance between mounting facilities parallel to length
  • 2.250 inches center to center distance between mounting facilities parallel to width
  • 3.130 inches overall height
L291532-6K NSN 6625-00-648-9614 Cross Reference: L291532-6REVJ
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.650 inches overall length
  • 0.125 inches mounting hole diameter
  • 12 single indicator single range scale division quantity
94-4357 NSN 6625-00-649-9279
  • dc circuit current for which designed
  • 2.063 inches overall length
  • 0.150 inches mounting hole diameter
  • 50 single indicator 2nd range scale division quantity
  • 3.500 inches overall diameter
1841-520545 NSN 6625-00-663-6208 Cross Reference: 141407, 841-23
  • nonhardened nuclear hardness critical feature
  • test set, elect. equip. fsc application data
US01-9 NSN 6625-00-668-4686 Cross Reference: M-1573, TDHR
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.250 inches overall length
  • 0.166 inches mounting hole diameter
  • 3.468 inches overall diameter
HS2 NSN 6625-00-669-1813
  • dc circuit current for which designed
  • 1.466 inches overall length
  • 0.438 inches mounting stud length
  • 2.675 inches overall diameter
  • 2.440 inches mounting bolt circle diameter
12Z13182-23 NSN 6625-00-673-5571 Cross Reference: G281708
  • ac circuit current for which designed
  • 2.250 inches overall length
  • 0.150 inches mounting hole diameter
  • 3.500 inches overall diameter
  • 3.000 inches mounting bolt circle diameter
9073414 NSN 6625-00-679-0888 Cross Reference: 1880TYPE21, MDE3-1
  • dc circuit current for which designed
  • 6.203 inches overall length
  • 4.312 inches center to center distance between mounting facilities parallel to length
  • 0.906 inches center to center distance between mounting facilities parallel to width
  • 1.250 inches overall height
46-250R NSN 6625-00-683-9542 Cross Reference: 1539, 260539, 462-135, 7709299P10
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.820 inches overall length
  • 0.150 inches mounting hole diameter
  • 90 single indicator single range scale division quantity