Special Scale Meters - Page 5 of 95

2357 part numbers
458-0856-020 NSN 6625-00-213-8575 Cross Reference: 2452-067, 623-16489
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.825 inches overall length
  • 0.125 inches mounting hole diameter
  • 40 single indicator single range scale division quantity
458-0856-030 NSN 6625-00-213-8601 Cross Reference: 2452-065, 2453-065, 623-16490
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.690 inches overall length
  • between 0.120 inches and 0.130 inches mounting hole diameter
  • 76 single indicator single range scale division quantity
VHZ NSN 6625-00-214-5749 Cross Reference: 2319739940, 55-74, SM-C-730305, VH3
  • ac circuit current for which designed
  • 3.000 inches overall length
  • 3.520 inches overall height
  • 4.120 inches overall width
  • 0.149 inches mounting hole diameter
8537 NSN 6625-00-226-2134 Cross Reference: 200-11383, 717299-028, 717299-28, CAL3, PRD13
  • dc circuit current for which designed
  • 2.375 inches overall length
  • 0.112 inches mounting hole diameter
  • 2.656 inches overall diameter
  • 2.094 inches mounting bolt circle diameter
168848 NSN 6625-00-228-9056
  • dc circuit current for which designed
  • 3500.0 dielectric withstanding voltage in volts
  • 2.250 inches overall length
  • 2 single indicator single range scale division quantity
  • 2.218 inches overall diameter
6508-6113-1 NSN 6625-00-229-7056
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.650 inches overall length
  • 0.125 inches mounting hole diameter
  • 20 single indicator 1st range scale division quantity
R-230 NSN 6625-00-229-7057 Cross Reference: 6508-6114-1
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.650 inches overall length
  • 0.125 inches mounting hole diameter
  • 12 single indicator single range scale division quantity
6508-6014-1 NSN 6625-00-229-7058
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 1.400 inches overall length
  • 0.125 inches mounting hole diameter
  • 22 single indicator single range scale division quantity
1539CLASS51 NSN 6625-00-231-8810 Cross Reference: 33548, 633-E571, M-2186
1120-1495 NSN 6625-00-232-0932
  • ac circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 2.312 inches overall length
  • 0.500 inches overall height
  • 1.906 inches overall width
5911046 NSN 6625-00-239-5305
17B3 NSN 6625-00-240-5487 Cross Reference: 115715, 17AT10B, 17B2, 17B2A, 17B502A, 17B503, 841TYPE2N, AN5536T1A
  • nonhardened nuclear hardness critical feature
  • test set, elect. equip. fsc application data
2605928 NSN 6625-00-242-6888 Cross Reference: 621-15482, S09392
  • dc circuit current for which designed
  • 3000.0 dielectric withstanding voltage in volts
  • 2.650 inches overall length
  • between 0.120 inches and 0.130 inches mounting hole diameter
  • 6 single indicator 1st range scale division quantity
722056 NSN 6625-00-242-8478
9-0163-001 NSN 6625-00-245-2975 Cross Reference: 810003-107
ST4325015HE0021 NSN 6625-00-246-5883
30-014058 NSN 6625-00-252-0049 Cross Reference: 260945, 515-0115
  • dc circuit current for which designed
  • 1500.0 dielectric withstanding voltage in volts
  • 2.094 inches overall length
  • 0.150 inches mounting hole diameter
  • 35 single indicator single range scale division quantity
M-1003 NSN 6625-00-252-3033 Cross Reference: 10625B03
  • dc circuit current for which designed
  • 500.0 dielectric withstanding voltage in volts
  • 2.550 inches overall length
  • 4.000 inches center to center distance between mounting facilities parallel to length
  • 3.560 inches center to center distance between mounting facilities parallel to width
4376-00 NSN 6625-00-255-1065 Cross Reference: 458-0792-010, 904376 0286, S4395
  • dc circuit current for which designed
  • 1.688 inches overall length
  • 1.800 inches center to center distance between mounting facilities parallel to length
  • 1.800 inches center to center distance between mounting facilities parallel to width
  • 2.594 inches overall height
M-2422 NSN 6625-00-257-1707 Cross Reference: 208780, 208780-1
218PT2223-1 NSN 6625-00-273-1657
  • dc circuit current for which designed
  • 2600.0 dielectric withstanding voltage in volts
  • 1.950 inches overall length
  • 3.010 inches overall height
  • 3.510 inches overall width
C219M77 NSN 6625-00-287-5057 Cross Reference: 219M77, 580-553
10179224-2 Height Meter NSN 6625-00-304-4318
  • dc circuit current for which designed
  • 4.613 inches overall length
  • 2.375 inches overall height
  • 3.125 inches overall width
  • 60 single indicator single range scale division quantity
1080H10H01 NSN 6625-00-310-1519 Cross Reference: 1080H10 PT H01, 1080H35H22, 88101 PC 04
  • zzzy criticality code justification
1080H10H04 NSN 6625-00-310-1521 Cross Reference: 1080H35H25
  • zzzy criticality code justification