8693-099-099 NSN 6685-00-907-1554 Cross Reference: 8693-099-099S, MODEL8693-S
  • calibrated to iron constantan thermocouple scale calibration
  • drum scale type
  • 1.0 degrees fahrenheit scale smallest increment
  • potentiometer circuit measurement type
  • 27.500 inches scale length
070205 NSN 6685-00-914-2345 Cross Reference: 8694-2-899, 8694-899
  • 9.500 inches overall length
  • 6.250 inches overall height
  • 7.250 inches overall width
  • calibrated to iron constantan thermocouple scale calibration
  • horizontal scale type
H3048 NSN 6685-00-918-2787 Cross Reference: 6799215-9
71000112 NSN 6685-00-918-9308
34 NSN 6685-00-920-0062
11902651 NSN 6685-00-937-5337
355 NSN 6685-00-938-2158 Cross Reference: 106C7481, 106C7481P1, 106C7481P2, 35-6124-0000
  • 2.350 inches overall depth
  • 3.580 inches overall diameter
  • 0.150 inches unthreaded mounting hole diameter
  • 3.160 inches mounting bolt circle diameter
  • calibrated to copper constantan thermocouple scale calibration
80241 NSN 6685-00-948-4759 Cross Reference: 002761, 10164, 80241-7551-85
  • 6.250 inches overall depth
  • 8.310 inches overall length
  • 5.000 inches overall width
  • 0.188 inches unthreaded mounting hole diameter
  • calibrated to iron constantan thermocouple scale calibration
388-3L NSN 6685-00-975-4544
  • 2.938 inches overall depth
  • 7.938 inches overall length
  • 6.000 inches overall width
  • calibrated to iron constantan thermocouple scale calibration
  • eccentric scale type
8692-099M NSN 6685-00-978-0793 Cross Reference: 8692E1C64-63-302, A15833-001, A16065-001
  • between 7.531 inches and 7.593 inches overall height
  • between 8.875 inches and 8.937 inches overall width
  • 4920-00-944-8354 end application
  • calibrated in 0.1 mv increments scale calibration
  • drum scale type
DHS-24-XF-FM NSN 6685-00-978-2853 Cross Reference: 409483-1, DHS-24-XF, DHSA24X
  • arc scale type
  • thermoelectrical circuit measurement type
  • carrying case w/handle case type
  • porm 1/2 of 1 pct of full scale scale accuracy rating
  • +0.000/+400.000 degrees fahrenheit scale measurement range
2745 NSN 6685-00-982-2843
  • 15.375 inches overall length
  • 7.500 inches overall height
  • 7.500 inches overall width
  • drum scale type
  • 0.001 millivolts and 0.005 millivolts scale smallest increment
41-8904-0000 NSN 6685-00-993-9780 Cross Reference: 451
218-00120-101 NSN 6685-01-012-4233
  • 5.100 millimeters overall length
  • 1 pct accuracy full scale scale accuracy rating
602.050.011 NSN 6685-01-013-2057 Cross Reference: 218-00120-101, 4000A
  • 510.0 millimeters overall length
  • 90.0 millimeters overall height
  • 180.0 millimeters overall width
  • arc scale type
  • 5.0 degrees fahrenheit scale smallest increment
869-3-2-502-502 NSN 6685-01-016-1310 Cross Reference: 8693-009-009
  • thermoelectrical circuit measurement type
  • +0.000/+400.000 degrees fahrenheit scale measurement range
SM-A-717621 NSN 6685-01-018-0079 Cross Reference: TSI-1000-5-22
  • 0.500 inches overall depth
  • 4.000 inches overall length
  • 3.510 inches overall diameter
  • 2.900 inches mounting bolt circle diameter
  • unc mounting facility screw thread series designator
43-8204-0000 NSN 6685-01-027-9098
  • 4.540 inches overall length
  • 2.480 inches overall height
  • 2.980 inches overall width
  • calibrated to iron constantan thermocouple scale calibration
  • concentric arc dial scale type
33594-1 NSN 6685-01-035-5614
  • 4.093 inches overall depth
  • 3.125 inches overall diameter
  • 0.169 inches unthreaded mounting hole diameter
  • 3.500 inches mounting bolt circle diameter
  • dial scale type
8505-20 NSN 6685-01-040-7090
  • broad arc dial scale type
  • 0.010 degrees celsius scale smallest increment
  • thermoelectrical circuit measurement type
  • box w/handle case type
  • -200.000/+400.000 degrees celsius scale measurement range
4220S004-3 NSN 6685-01-042-3526 Cross Reference: 445-011, 643-16766
  • electric power generation sys end application
  • meter dial scale type
  • 25.0 degrees fahrenheit scale smallest increment
  • dripproof case type
  • 1 pct entire range scale accuracy rating
4220S004-9 NSN 6685-01-042-3527 Cross Reference: 445-008, 643-16769
  • electric power generation sys end application
  • meter dial scale type
  • 10.0 degrees fahrenheit scale smallest increment
  • dripproof case type
  • 1 pct entire range scale accuracy rating
4220S004-13 NSN 6685-01-042-3528 Cross Reference: 445-012, 643-16771
  • electric power generation sys end application
  • meter dial scale type
  • 25.0 degrees fahrenheit scale smallest increment
  • dripproof case type
  • 1 pct entire range scale accuracy rating
4220S004-11 NSN 6685-01-042-3529 Cross Reference: 445-013, 643-16770
  • meter dial scale type
  • 25.0 degrees fahrenheit scale smallest increment
  • dripproof case type
  • 1 pct entire range scale accuracy rating
4000A NSN 6685-01-048-3418 Cross Reference: 4000A/0-1600 DEG F
  • concentric arc dial scale type
  • 20.000 degrees fahrenheit scale smallest increment
  • thermoelectrical circuit measurement type
  • 3.375 inches scale length
  • carrying case w/handle case type